CivArchive
    Preview 33160046
    Preview 33160157
    Preview 33160310
    Preview 33160389
    Preview 33160448
    Preview 33160650
    Preview 33525949
    Preview 33526086
    Preview 33526182
    Preview 33526260
    Preview 33539335
    Preview 33539882

    Hello there and thanks for checking out this workflow!

    What's new in v27? : Major rework with new SubGraphs to streamline and compact the workflow even more, removal of outdated/broken nodes + fixes and optimizations all over!

    Purpose

    Built to provide an advanced, versatile and modular workflow for Flux with focus on efficiency, structure and information.

    It comes with many notes explaining node settings and recommendations, as well as general guides from instructions to troubleshooting.

    Features

    • Convenient loaders for all common versions of Flux and Clip models

    • Full metadata; recognized by CivitAI

    • LoRA support

    • SageAttention, EasyCache + Model Compile acceleration

    • ControlNet with Union support

    • Flux Tools LoRAs Canny + Depth (alt. to CNet based on LoRA)

    • Flux Redux (similar to IPAdapter)

    • PuLID (SVDQuant version only)

    • Wildcard prompting

    • Installation and download guide for models and nodes

    • multiple passes with optional upscales

    • 1st : Detail Daemon + Variation Seed

    • 2nd : DD. + Tiled Diffusion / UltimateSDUpscale

    • ADetailer with dedicated LoRA Loader

    • Inpainting

    Custom Nodes

    All of which can be installed through the ComfyUI-Manager

    Troubleshooting

    1. If nodes show up red (failing to load), check the 'Install Missing Custom Nodes' tab of the ComfyUI Manager for the missing node packs and install them.

    2. Please check if all custom node packs load properly after installing, i.e. no (IMPORT FAILED) messages next to any of them in the console upon ComfyUI startup.

    3. Always reload/drag'n'drop the original, downloaded workflow file into ComfyUI to reload an intact version of the workflow.

      → The last opened workflow that appears on startup shows a cached version of the workflow, "remembering" group nodes that failed due to missing nodes as failed, keeping them broken even after having everything installed correctly.


    Thanks

    The workflow would not be possible as is without these custom node packs. If you want to support the custom node creators, give them a ⭐ on their github repos! Thank you!


    Feel free to ask questions, share improvements and suggestions in the comment section!
    Let me know if you encounter confusing points I can elaborate on in the next update!

    Description

    v11
    — major restructure of loaders setup
    — having one of each Flux version is no longer necessary

    v11.1
    — replaced dual clip loaders with .gguf capable variant

    v11.2
    — enabled vae input for ControlNet — AIO
    — added missing node-pack reference to comfyui_controlnet_aux

    FAQ

    Comments (7)

    blue_zima_blueOct 6, 2024· 1 reaction
    CivitAI

    v11 is working great, thanks! Can you add support for gguf version of T5 clip with this?

    RedPinkRetro
    Author
    Oct 6, 2024

    Glad to hear! Oh, of course! Going back to the old loaders I forgot to switch to the gguf-capable clip-loader! I will fix that right away. Should be up as 11.1 in about 20-30 minutes 😅

    RedPinkRetro
    Author
    Oct 6, 2024· 1 reaction

    @blue_zima_blue .gguf clip support added 👌

    blue_zima_blueOct 7, 2024· 1 reaction

    Noticed couple of issues:
    - Depth anything auto download not working, had to download manually
    - After downloading getting error that AIO controlnet requires vae

    RedPinkRetro
    Author
    Oct 7, 2024· 1 reaction

    @blue_zima_blue the depth anything download is coded into the controlnet_aux node pack itself, so I can not do much about that. However the downloads all worked for me without issues.
    The only one that does not work, as it is yet to be released, is the "g" variant that is for some reason in the dropdown menu.
    The one's working are "....s" → small, "....b" → base and "....l" → large, while "....g" → giant (or something) is not out yet.

    The controlnet group actually insisting on the VAE is new to me though. It does not have any issues on my end with that. Either way I enabled the VAE input and uploaded v11.2

    Please tell me if that actually makes a difference in your case or if the problem persists.

    blue_zima_blueOct 8, 2024· 1 reaction

    @redpinkretro it works now however had to link the image node for AIO controlnet manually. Thanks.

    RedPinkRetro
    Author
    Oct 8, 2024· 1 reaction

    @blue_zima_blue Alright, good to know that VAE input does something for some users at least 😅
    Yes, sorry about that. Forgot to re-attach it properly in the hurry,... again. Uploaded a fixed version under the same 11_2 version with an intact connection. Thank you 👌

    Workflows
    Flux.1 D

    Details

    Downloads
    222
    Platform
    CivitAI
    Platform Status
    Available
    Created
    10/6/2024
    Updated
    5/7/2026
    Deleted
    -

    Files

    comfyuiFluxAdvanced_v112.zip

    Mirrors

    CivitAI (1 mirrors)

    comfyuiFlux1Advanced_v11.zip

    Mirrors

    CivitAI (1 mirrors)